This repository covers all files that were made and used for Deep learning modeling attenuation scatter correction of 68Ga-PSMA PET/CT. This project at artificial intelligence in cardiac imaging laboratory, Inselspital, University of Bern, was done for fulfilment of the master of Data science for life science at Hanze University of Applied Science.

License

Notifications You must be signed in to change notification settings

s-shahpouri/DL_PET

Repository files navigation

Deep Learning-Based PET Image Correction Toward Quantitative Imaging

Introduction

This repository contains the code and documentation for the master thesis project, which focuses on developing a deep learning model to correct attenuation and scatter corrections without anatomical inforamtion from CT, also detect and correct artefacts in 68Ga-PET imaging. In this thesis, we have demonstrated the efficacy of an Integrated multi-center Dynamic Unet DL framework for artifact detection and correction in PET imaging of 68Ga-labelled compounds. The approach leverages large datasets from multiple centers, to achive a universal model for same radiotracer but different centers. Through the incorporation of transfer learning concepts, we have developed radiotracer-specific models that significantly outperform those based on specific radiotracers, thereby addressing a major limitation in the field of medical imaging. Our model effectively detected and corrected artifacts. This enhancement is vital for making therapeutic decisions in the field of oncology, where PET imaging plays a central role in diagnosing, planning treatments, and evaluating responses. By using Dyn-Unet architecture and other advanced DL techniques, our method has not only improved image quality but also greatly decreased the appearance of common artifacts like halo and mismatch artifacts, especially in 68Ga-PET imaging. The effective implementation of our models in different centers highlights their resilience and flexibility, which are essential for general acceptance in clinical settings.

Objectives

In this study we tried to take a step into the problematic field of correction in PET imaging artefacts, with especially high-prevalence ones: mismatch and halo artefacts in 68Ga PET imaging. The aim of this paper is to look at several deep learning models and methodologies to design a multi-centre model that allows un-direct data sharing at each centre due to some demerits of conventional deep learning techniques. We will use our approach to estimate and compare the performance of models under both strategies within different radio tracer distributions and multi-centre data environments. This research will aim to be a demonstration of the possibility, as well as the superior performance, of the deep learning models for real clinical settings, which will potentially set a new standard of CT-free PET imaging that enhances diagnostic accuracy while minimising radiation exposure and procedural complexity.

Models

  • Integrated Multi-Center Model (IMCM): Combines data from multiple centers to enhance model generalization.
  • Anatomy-Dependent Correction Model (ADCM): Focuses on correcting attenuation and scatter based on anatomical features.
  • Tuned Transfer Learning Model (TL-MC): Addresses the variability across different radiotracers.

Project Structure

  • src/: Source code for the deep learning models and utility functions.
  • data/: Sample data files (note: due to privacy, actual patient data are not included).
  • Archive/: Archived notbooks nessasary for further investigation.
  • Analysis/: Archived notbooks about data pre processing, statistical testing and so on.
  • Other_Models/: Archived models notbooks we could'nt get good results or needing for further progress.
  • info/: Documentation and additional notes on the project.
  • Results/: Analysis output, plots, model structure and images used in the thesis for demonstration, such as artefact corrections.

Setup and Installation

Ensure you have Python 3.8+ installed, then run:

pip install -r requirements.txt

Usage To train the model:

python src/main.py

To evaluate the model:

python Inference.ipynb

To use the application:

streamlit run dashboard.py

Results

This project achieved notable improvements in artefact detection and attenuation/scatter correction. Refer to the results/ directory for detailed performance metrics and visual results.

Artifact Correction Demonstration

This section showcases the results of the artifact correction applied using the IMCM model:

Artifact Correction

License

This project is licensed under the MIT License - see the LICENSE.md file for details.

Acknowledgments

Thesis Supervisors

Dr. Isaac Shiri

Dr. Dave Langers

Data contributors

Artificial Intelligence in Cardiac Imaging Laboratory, Inselspital, Bern University Hospital, Switzerland

Hanze University of applied science, Groningen, The Netherlands

Contact

Author: Sama Shahpouri

Email: [[email protected]]

About

This repository covers all files that were made and used for Deep learning modeling attenuation scatter correction of 68Ga-PSMA PET/CT. This project at artificial intelligence in cardiac imaging laboratory, Inselspital, University of Bern, was done for fulfilment of the master of Data science for life science at Hanze University of Applied Science.

Topics

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages