-
Notifications
You must be signed in to change notification settings - Fork 505
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- Loading branch information
1 parent
c3789a4
commit 2e4de89
Showing
755 changed files
with
160,887 additions
and
33,683 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,37 +1,37 @@ | ||
<?xml version='1.0' encoding='UTF-8'?> | ||
<!-- This document was created with Syntext Serna Free. --><!DOCTYPE topic PUBLIC "-//OASIS//DTD DITA Topic//EN" "http://docs.oasis-open.org/dita/v1.1/OS/dtd/topic.dtd" []> | ||
<topic id="nsis" xml:lang="en-us"> | ||
<title>NullSoft Scritable Install System - Installation Tool</title> | ||
<prolog> | ||
<author>Ratnadip Choudhury</author> | ||
<copyright> | ||
<copyryear year="2011"/> | ||
<copyrholder>ROBERT BOSCH ENGINEERING AND BUSINESS SOLUTIONS LIMITED</copyrholder> | ||
</copyright> | ||
</prolog> | ||
<body> | ||
<section> | ||
<title>Description</title> | ||
<p>NullSoft Scriptable Install System (NSIS) is the <xref href="http://en.wikipedia.org/wiki/List_of_installation_software" scope="external">software installation framework</xref> used. It is a script-driven Windows installation system. The following links may be accessed for details:</p> | ||
</section> | ||
<section> | ||
<title>Download</title> | ||
<p>The NSIS installer is available for download at <xref href="http://nsis.sourceforge.net/" scope="external"/>. The latest version is 2.46, dated December 06, 2009.</p> | ||
</section> | ||
<section> | ||
<title>Installation</title> | ||
<p>Just run the <filepath>nsis-2.46-setup.exe</filepath>. The standard installation folder is <filepath>%ProgramFiles%\NSIS</filepath>.</p> | ||
</section> | ||
<section> | ||
<title>Configuration</title> | ||
<p>There is no specific configuration necessary.</p> | ||
</section> | ||
<section> | ||
<title>Usage</title> | ||
<p>The BUSMASTER install script is located under <filepath>Installation Setup\BUSMASTER Install Script.nsi</filepath>.</p> | ||
<p>The setup is depicted in the diagram below which shows how the installer build generation process is initiated by User and how the script accesses the artifacts from various locations under the <filepath>Sources</filepath> and <filepath>Documents\4 Help</filepath> folder. Prior to building the script, the artifacts needs to be generated by building the BUSMASTER application in Visual studio environment (VC++) and DITA-OT.<image href="../images/installation.png" placement="break"/></p> | ||
<title>Dependency</title> | ||
<p>Install script expects Visual Studio 2012 Redistributable package to be available under the folder Tools\VC++ 2012 Redistributable\vcredist_x86.exe</p> | ||
</section> | ||
</body> | ||
</topic> | ||
<?xml version='1.0' encoding='UTF-8'?> | ||
<!-- This document was created with Syntext Serna Free. --><!DOCTYPE topic PUBLIC "-//OASIS//DTD DITA Topic//EN" "http://docs.oasis-open.org/dita/v1.1/OS/dtd/topic.dtd" []> | ||
<topic id="nsis" xml:lang="en-us"> | ||
<title>NullSoft Scritable Install System - Installation Tool</title> | ||
<prolog> | ||
<author>Ratnadip Choudhury</author> | ||
<copyright> | ||
<copyryear year="2011"/> | ||
<copyrholder>ROBERT BOSCH ENGINEERING AND BUSINESS SOLUTIONS LIMITED</copyrholder> | ||
</copyright> | ||
</prolog> | ||
<body> | ||
<section> | ||
<title>Description</title> | ||
<p>NullSoft Scriptable Install System (NSIS) is the <xref href="http://en.wikipedia.org/wiki/List_of_installation_software" scope="external">software installation framework</xref> used. It is a script-driven Windows installation system. The following links may be accessed for details:</p> | ||
</section> | ||
<section> | ||
<title>Download</title> | ||
<p>The NSIS installer is available for download at <xref href="http://nsis.sourceforge.net/" scope="external"/>. The latest version is 2.46, dated December 06, 2009.</p> | ||
</section> | ||
<section> | ||
<title>Installation</title> | ||
<p>Just run the <filepath>nsis-2.46-setup.exe</filepath>. The standard installation folder is <filepath>%ProgramFiles%\NSIS</filepath>.</p> | ||
</section> | ||
<section> | ||
<title>Configuration</title> | ||
<p>There is no specific configuration necessary.</p> | ||
</section> | ||
<section> | ||
<title>Usage</title> | ||
<p>The BUSMASTER install script is located under <filepath>Installation Setup\BUSMASTER Install Script.nsi</filepath>.</p> | ||
<p>The setup is depicted in the diagram below which shows how the installer build generation process is initiated by User and how the script accesses the artifacts from various locations under the <filepath>Sources</filepath> and <filepath>Documents\4 Help</filepath> folder. Prior to building the script, the artifacts needs to be generated by building the BUSMASTER application in Visual studio environment (VC++) and DITA-OT.<image href="../images/installation.png" placement="break"/></p> | ||
<title>Dependency</title> | ||
<p>Install script expects Visual Studio 2012 Redistributable package to be available under the folder Tools\VC++ 2012 Redistributable\vcredist_x86.exe</p> | ||
</section> | ||
</body> | ||
</topic> |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
32 changes: 32 additions & 0 deletions
32
Documents/4 Help/topics/FlexRay_Cluster_Configuration.dita
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,32 @@ | ||
<?xml version='1.0' encoding='UTF-8'?> | ||
<!-- This document was created with Syntext Serna Free. --><!DOCTYPE topic PUBLIC "-//OASIS//DTD DITA Topic//EN" "http://docs.oasis-open.org/dita/v1.1/OS/dtd/topic.dtd" [ | ||
<!ENTITY Introduction '<xref/>'>]> | ||
<topic id="signal_watch" xml:lang="en-us"> | ||
<title>Cluster Configuration</title> | ||
<prolog> | ||
<author/> | ||
<copyright> | ||
<copyryear year="2013"/> | ||
<copyrholder>ROBERT BOSCH ENGINEERING AND BUSINESS SOLUTIONS LIMITED</copyrholder> | ||
</copyright> | ||
<metadata> | ||
<keywords> | ||
<indexterm>FlexRay Cluster Configuration</indexterm> | ||
</keywords> | ||
</metadata> | ||
</prolog> | ||
<body> | ||
<p><b>Introduction:</b></p> | ||
<p>To connect BUSMASTER to the FlexRay Network first it has to be configured with the proper FIBEX File.This can be done using <b>Cluster Configuration window</b>.</p> | ||
<p><b>Configuration:</b></p> | ||
<p>To configure the Cluster use <b>FlexRay->Cluster Configuration</b> menu.This will display the Window as shown in following Figure.</p> | ||
<p/> | ||
<image href="../images/FlexRay_ClusterConfig_Empty.bmp"/> | ||
<p><b>Adding FIBEX File:</b></p> | ||
<p>Click the Browse button as shown in above figure to add the FIBEX File.Once the file is added the Window will display the Clusters available in <b>Select FlexRay Cluster</b> combo box. The <b>Select ECU</b> List Box will display all ECUs configured for the selected cluster.An Example Cluster Configuration is shown in following figure.</p> | ||
<p>Current BUSMASTER Supports FIBEX Versions 2.0, 3.0, 4.0.</p> | ||
<p/> | ||
<image href="../images/FlexRay_ClusterConfig_Example.bmp"/> | ||
<p>ECU <b>Send</b> is selected for Simulation in BUSMASTER.So all the Tx Message configured for <b>Send</b> ECU will be available for transmission in Tx Window.Check <b>FlexRay Transmission Window</b> Topic for more information on How to Transmit the FlexRay Messages over FlexRay Bus.</p> | ||
</body> | ||
</topic> |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,33 @@ | ||
<?xml version='1.0' encoding='UTF-8'?> | ||
<!-- This document was created with Syntext Serna Free. --><!DOCTYPE topic PUBLIC "-//OASIS//DTD DITA Topic//EN" "http://docs.oasis-open.org/dita/v1.1/OS/dtd/topic.dtd" [ | ||
<!ENTITY Introduction '<xref/>'>]> | ||
<topic id="signal_watch" xml:lang="en-us"> | ||
<title>FlexRay Controller Configuration</title> | ||
<prolog> | ||
<author/> | ||
<copyright> | ||
<copyryear year="2013"/> | ||
<copyrholder>ROBERT BOSCH ENGINEERING AND BUSINESS SOLUTIONS LIMITED</copyrholder> | ||
</copyright> | ||
<metadata> | ||
<keywords> | ||
<indexterm>FlexRay Transmit Window</indexterm> | ||
</keywords> | ||
</metadata> | ||
</prolog> | ||
<body> | ||
<p><b>Introduction:</b></p> | ||
<p>BUSMASTER Can be connected to FlexRay physical channel using FlexRay Controller.</p> | ||
<p>Currently BUSMASTER Supports the following FlexRay Controllers.</p> | ||
<p><ol> | ||
<li> ETAS BOA Controllers.</li> | ||
</ol></p> | ||
<p><b>Selecting Controller:</b></p> | ||
<p>Before Selecting the controlletr the BUSMASTER has to be configured with the proper FIBEX File.Refer <b>Cluster Configuration</b> for more information.</p> | ||
<p>To select controller use FlexRay->Driver Selection-><i>{Driver}</i> For example to select ETAS BOA Driver use <b>FlexRay->Driver Selection->ETAS BOA.</b>If only one controller is connected to PC that controller will be selected automatically.Otherwise Hardware Selection window with all the available controllers will be displayed as shown in following figure.</p> | ||
<p/> | ||
<image href="../images/FlexRay_Hardware_Selection.bmp"/> | ||
<p/> | ||
<p>Once the Cluster & Controller is configured BUSMASTER Can be connected to FlexRay network using <b>FlexRay->Connect</b> Menu.If any Error occur during the initialisation of Controller the information will be displayed in BUSMASTER Trace Window.</p> | ||
</body> | ||
</topic> |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,26 @@ | ||
<?xml version='1.0' encoding='UTF-8'?> | ||
<!-- This document was created with Syntext Serna Free. --><!DOCTYPE topic PUBLIC "-//OASIS//DTD DITA Topic//EN" "http://docs.oasis-open.org/dita/v1.1/OS/dtd/topic.dtd" [ | ||
<!ENTITY Introduction '<xref/>'>]> | ||
<topic id="signal_watch" xml:lang="en-us"> | ||
<title>FlexRay</title> | ||
<prolog> | ||
<author>Ratnadip Choudhury</author> | ||
<copyright> | ||
<copyryear year="2012"/> | ||
<copyrholder>ROBERT BOSCH ENGINEERING AND BUSINESS SOLUTIONS LIMITED</copyrholder> | ||
</copyright> | ||
<metadata> | ||
<keywords> | ||
<indexterm>Signal Graph</indexterm> | ||
</keywords> | ||
</metadata> | ||
</prolog> | ||
<body> | ||
<section> | ||
<title>Introduction</title> | ||
<ul> | ||
<li/> | ||
</ul> | ||
</section> | ||
</body> | ||
</topic> |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,118 @@ | ||
<?xml version='1.0' encoding='UTF-8'?> | ||
<!-- This document was created with Syntext Serna Free. --><!DOCTYPE topic PUBLIC "-//OASIS//DTD DITA Topic//EN" "http://docs.oasis-open.org/dita/v1.1/OS/dtd/topic.dtd" [ | ||
<!ENTITY Introduction '<xref/>'>]> | ||
<topic id="signal_watch" xml:lang="en-us"> | ||
<title>FlexRay Message Window</title> | ||
<prolog> | ||
<author/> | ||
<copyright> | ||
<copyryear year="2013"/> | ||
<copyrholder>ROBERT BOSCH ENGINEERING AND BUSINESS SOLUTIONS LIMITED</copyrholder> | ||
</copyright> | ||
<metadata> | ||
<keywords> | ||
<indexterm>FlexRay Transmit Window</indexterm> | ||
</keywords> | ||
</metadata> | ||
</prolog> | ||
<body> | ||
<p><b>Introduction:</b></p> | ||
<p>On-line FlexRay Network Monitoring can be done using FlexRay Message window.</p> | ||
<p><b>Activation:</b></p> | ||
<p>Use <b>FlexRay->Message Window->Activate</b> menu to Activate the Message window.This will display Message Window as shown in following figure.</p> | ||
<p><image href="../images/FlexRay_MessageWindow_Empty.bmp"/></p> | ||
<p>Once the BUSMASTER is connected to FlexRay Network the Message window will display all the Messages Transmitted on the network.The Messages can also display the message interpretation. </p> | ||
<p><b>Enabling Interpretation:</b></p> | ||
<p>To enable the interpretation the Message window should be in overwrite mode.Use <b>FlexRay->Message Window->Overwrite</b>. menu to enable the overwrite mode.After this use <b>FlexRay->Message Window->Interpret.</b></p> | ||
<p/> | ||
<p>The below figure shows Message window when it BUSMASTER is connected to FlexRay Network.</p> | ||
<image href="../images/FlexRay_MessageWindow_Online.bmp"/> | ||
<p>The Following section will explain the Columns Displayed in Message window with explanation.</p> | ||
<p><table frame="all"> | ||
<title/> | ||
<tgroup cols="2"> | ||
<colspec colname="c1"/> | ||
<colspec colname="c2"/> | ||
<thead> | ||
<row> | ||
<entry>Column</entry> | ||
<entry>Explanation</entry> | ||
</row> | ||
</thead> | ||
<tbody> | ||
<row> | ||
<entry> | ||
<b>Time</b> | ||
</entry> | ||
<entry>This Will display the time at which message is received\Sent on FlexRay BUS.The time mode can be changed to Absolute\System\Relative Mode using <b>FlexRay->Message Window->Time Mode</b> menu</entry> | ||
</row> | ||
<row> | ||
<entry> | ||
<b>Tx/Rx</b> | ||
</entry> | ||
<entry>This Menu will display weather the message is received or sent from BUSMASTER.Tx Represents the message is sent From BUSMASTER.Rx Represent Message is received in BUSMASTER</entry> | ||
</row> | ||
<row> | ||
<entry> | ||
<b>Frame Id</b> | ||
</entry> | ||
<entry>This Column gives the information about the Scheduling of Message.The information will be displayed in the format of <b><i>slot_id [base_cycle, repetition]</i>.</b></entry> | ||
</row> | ||
<row> | ||
<entry> | ||
<b>Frame Type</b> | ||
</entry> | ||
<entry>This Column will tell the Frame type.The following are the Frame types displayed in this column. <ul> | ||
<li>sync</li> | ||
<li>startup</li> | ||
<li>sync, startup</li> | ||
<li>Null</li> | ||
<li>Data</li> | ||
</ul></entry> | ||
</row> | ||
<row> | ||
<entry> | ||
<b>Slot Type</b> | ||
</entry> | ||
<entry> | ||
<p>This column will tell weather the message is Transmitted\Received in static\Dynamic Slot.</p> | ||
</entry> | ||
</row> | ||
<row> | ||
<entry> | ||
<p><b>Description</b></p> | ||
</entry> | ||
<entry>This column will give the Message Name associated with the ID.</entry> | ||
</row> | ||
<row> | ||
<entry> | ||
<b>Cycle</b> | ||
</entry> | ||
<entry>This column will display the Cycle in which the message was received </entry> | ||
</row> | ||
<row> | ||
<entry> | ||
<b>Channel</b> | ||
</entry> | ||
<entry><b>:</b>This column will display on which channel ( A, B or AB ) the message was received.</entry> | ||
</row> | ||
<row> | ||
<entry> | ||
<b>DLC</b> | ||
</entry> | ||
<entry>This column will display the Length of Frame in Bytes.</entry> | ||
</row> | ||
<row> | ||
<entry> | ||
<b>Data Byte (s)</b> | ||
</entry> | ||
<entry>This column will display the Data Bytes received\Transmitted of the Frame</entry> | ||
</row> | ||
</tbody> | ||
</tgroup> | ||
</table></p> | ||
<p><b>Message Interpretation window:</b></p> | ||
<p>It is possible to Monitor the interpretation of a single message in separate window called <b>Message Interpretation.</b>Double click on any message in Message window to Activate the Message Interpretation window.An Instance of this window is shown in following figure.</p> | ||
<p><image href="../images/FlexRay_MessageWindow_Interpretation.bmp"/></p> | ||
</body> | ||
</topic> |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,38 @@ | ||
<?xml version='1.0' encoding='UTF-8'?> | ||
<!-- This document was created with Syntext Serna Free. --><!DOCTYPE topic PUBLIC "-//OASIS//DTD DITA Topic//EN" "http://docs.oasis-open.org/dita/v1.1/OS/dtd/topic.dtd" [ | ||
<!ENTITY Introduction '<xref/>'>]> | ||
<topic id="signal_watch" xml:lang="en-us"> | ||
<title>FlexRay Simulation in BUSMASTER</title> | ||
<prolog> | ||
<author/> | ||
<copyright> | ||
<copyryear year="2013"/> | ||
<copyrholder>ROBERT BOSCH ENGINEERING AND BUSINESS SOLUTIONS LIMITED</copyrholder> | ||
</copyright> | ||
<metadata> | ||
<keywords> | ||
<indexterm>FlexRay Transmit Window</indexterm> | ||
</keywords> | ||
</metadata> | ||
</prolog> | ||
<body> | ||
<p><b>Introduction:</b></p> | ||
<p>BUSMASTER can be used to Transmit or Receive (Monitor) the FlexRay messages.The following steps are required to Configure the BUSMASTER for Transmit\Receive the FlexRay Messages.</p> | ||
<p><b>1. Cluster Configuration:</b> </p> | ||
<p>To Transmit\Receive the FlexRay Messages a proper FIBEX File has to Imported in BUSMASTER.Refer <b>Cluster Configuration</b> Section for more Information.</p> | ||
<p/> | ||
<p><b>2. <b>Controller (Driver) Selection:</b></b></p> | ||
<p>BUSMASTER can be connected to Physical FlexRay Network using FlexRay Controller.Refer <b>Controller Selection</b> section for more Information.</p> | ||
<p/> | ||
<p><b>3. Connect to Network:</b></p> | ||
<p>Once the Cluster & Controllers are properly configured BUSMASTER can be connected to Network using <b>FlexRay->Connect</b>. menu or the FlexRay Connect Tool bar Button as shown in following figure.</p> | ||
<p/> | ||
<p><image href="../images/FlexRay_Connect.bmp"/></p> | ||
<p/> | ||
<p><b>4. Transmit Messages:</b></p> | ||
<p>FlexRay Messages Can be transmitted ovr FlexRay network using FlexRay Tx Window.Refer <b>FlexRay Transmission Window</b> Section for more information.</p> | ||
<p/> | ||
<p><b>5. Monitoring Messages:</b></p> | ||
<p>BUSMASTER Message Window can be used to monitor the FlexRay messages of FlexRay Network.Refer <b>FlexRay Message Window</b> section for more information.</p> | ||
</body> | ||
</topic> |
Oops, something went wrong.