- Product name: Maxbotix ultrasonic rangefinder
- Purpose: Measuring the depth to a water surface
- Tested Models: MB7383 (Short range) & MB7384 (Short range)
- Output variables:
maxbotix_depth
- Product website: http://www.maxbotix.com/Ultrasonic_Sensors/MB7383.htm
- Datasheet: http://www.maxbotix.com/documents/HRXL-MaxSonar-WR_Datasheet.pdf
- Pinout:
- Temperature sensor connection
- Pulse width output
- Analog voltage output
- Ranging start/stop
- Serial output
- Positive power (VCC)
- Ground
- Communication protocol: UART
- Notes: The short range sensor has a range of 300-5000 mm. The long-range sensor has a range of 500-9999 mm.
- Product name: Decagon GS3 ruggedized soil moisture, temperature, and electrical conductivity sensor
- Purpose: Measuring volumetric water content, conductivity, and temperature in soils.
- Tested Models: GS3
- Output variables:
decagon_soil_conduct
,decagon_soil_dielec
,decagon_soil_temp
- Product website: https://www.decagon.com/en/soils/volumetric-water-content-sensors/gs3-vwc-temp-ec/
- Datasheet: http://manuals.decagon.com/Manuals/13822_GS3_Web.pdf
- Pinout:
- Serial output
- Positive power (VCC)
- Ground
- Communication protocol: UART
- Official name: Hydreon RG-11 Optical Rain Sensor with relay interface
- Purpose: Detecting the presence of rain and measuring rainfall accumulation
- Tested models: RG-11
- Output variables:
hydreon_prcp
- Product website: http://store.hydreon.com/shop/rain-sensor/RG-11.html
- Datasheet: http://hydreon.com/wp-content/uploads/sites/3/2015/documents/rg-11_instructions.pdf
- Communication protocol: UART
- Note: To supply an adequate voltage, a 12V boost regulator such as this one is needed: https://www.pololu.com/product/2117
- Purpose: Measuring in-situ water temperature
- Output variables:
atlas_water_temp
- Product website: https://www.atlas-scientific.com/temperature.html
- Datasheet: https://www.atlas-scientific.com/_files/_datasheets/_circuit/EZO_RTD_Datasheet.pdf
- Communication protocol: I2C
- Purpose: Measuring in-situ pH of streams and ponds
- Output variables:
atlas_ph
- Product website: https://www.atlas-scientific.com/ph.html
- Datasheet: https://www.atlas-scientific.com/_files/_datasheets/_circuit/pH_EZO_datasheet.pdf
- Communication protocol: I2C
- Purpose: Measuring in-situ oxidation-reduction potential of streams and ponds
- Output variables:
atlas_orp
- Product website: https://www.atlas-scientific.com/orp.html
- Datasheet: https://www.atlas-scientific.com/_files/_datasheets/_circuit/ORP_EZO_datasheet.pdf
- Communication protocol: I2C
- Purpose: Measuring in-situ dissolved oxygen concentration of streams and ponds
- Output variables:
atlas_dissolved_oxygen
- Product website: https://www.atlas-scientific.com/dissolved-oxygen.html
- Datasheet: https://www.atlas-scientific.com/_files/_datasheets/_circuit/DO_EZO_datasheet.pdf
- Communication protocol: I2C
- Purpose: Measuring in-situ conductivity, salinity, total dissolved solids, and specific gravity of streams and ponds
- Output_variables:
atlas_ec
,atlas_sal
,atlas_tds
,atlas_sg
- Product website: https://www.atlas-scientific.com/conductivity.html
- Datasheet: https://www.atlas-scientific.com/_files/_datasheets/_circuit/EC_EZO_datasheet.pdf
- Communication protocol: I2C
- Purpose: Capturing in-situ water samples for lab analysis
- Output variables:
isco_bottle
- Tested models: Teledyne ISCO 3700 Full-size sampler
- Associated flags:
autosampler_flag
- Associated triggers:
autosampler_trigger
- Product website: http://www.teledyneisco.com/waterandwastewater/Pages/Portable-Samplers.aspx
- Datasheet: http://www.teledyneisco.com/waterandwastewater/Sampler%20Documents/Datasheets/Isco%203700%20Portable%20Full-size%20Sampler%20Datasheet.pdf