Skip to content

Real-time MAX30101 photoplethysmograph viewer and configuration tool.

License

Notifications You must be signed in to change notification settings

TEGSense/ppgview

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

2 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

PPGView

PPGView is a web utility to display realtime photoplethysmograph (PPG) readings from the MAX30101 sensor. It is also used to collect data and configure the device. The web interface connects to the sensor over a Bluetooth Low Energy (BLE) interface.

Interface screenshot

Features

These features assume the connected device supports all of these features (true for the firmware).

  • Red and infrared (IR) PPG waveform capture.
  • Device configuration options for ADC scaling, sample rate, pulse width, device averaging, and LED currents.
  • Single-shot or continuous measurement options.
  • Startup measurement delay.
  • Sensor settings stored to flash.
  • Real-time plotting with zooming, scrolling, and figure saving.
  • Input and output data capture.
  • Wireless BLE interface which handles device disconnects gracefully.

Limitations

Device compatibility

The software was developed to interface with an application-specific research device, although it's useful for any PPG application. This is configured to connect to a BLE device named "TEGSense" which uses the Nordic UART Service (NUS) to telemeter PPG waveforms and sensor configuration details. This can actually be any BLE device (Arduino or otherwise) that's configured to telemeter the data in the expected format (specified below). If you have a Noridc development board handy, you can also use the firmware available in the firmware repository. It will look for any device named "TEGSense" and try to connect to the first device that matches that criteria.

Future improvements:

  • Arduino firmware implementation.
  • Serial interface.
  • Support for device selection.

Sensor configuration

Currently, the device is configured to handle just the red and infrared (IR) measurements. The green LED or proximity modes cannot be enabled through this interface. You can also not initiate other sensor actions, like soft (or hard) resets or FIFO clears. The firmware implementation does offer the capability to store sensor settings to flash and reboot.

Future improvements:

  • Support green LED and proximity use cases.
  • Add support for device actions (reset, FIFO configuration).
  • Add SpO2, HR, and HRV computations.
  • Add filtering support.

Installation

If you run

pip install .

in the root directory, it will add a link to the ppgview application in your environment. Just run ppgview to start the web interface. You need Bluetooth enabled and it will immediately (and continuously) (and indiscriminantly) scan for devices named TEGSense then wait for them to send data. You just need a device with that name that sends data.

Data format

You don't have to use the original device or firmware, you can modify the code to use anything reasonably compatible, or configure your own device to package the data accordingly. The incoming packet format is defined in packet.py and currently looks like this (in little endian format):

time: uint32
pid: uint16
cfg: uint8
fifo_cfg: uint8
cp_cfg: uint8
red_pa: uint8
ir_pa: uint8
<pad>: byte
N: uint16
<pad>: byte * 2
red: uint32 * N
ir: uint32 * N

You fill find the MAX30101 datasheet helpful at this point.

  • time is the MCU timestamp (ms since startup) roughly corresponding to the first measurement.
  • pid is the packet ID.
  • cfg is the MAX30101 SpO2 configuration register (0x0A).
  • fifo_cfg is the MAX30101 FIFO configuration register (0x08).
  • cp_cfg is the collection mode configuration (see below).
  • red_pa is the MAX30101 red LED pulse amplitude configuration register (0x0C).
  • ir_pa is the MAX30101 IR LED pulse amplitude configuration register (0x0D).
  • N is the number of data samples (currently 50, and the device only sends full packets).
  • red is an array of N red photodetector ADC samples.
  • ir is an array of N IR photodetector ADC samples.

The collection mode configuration is split into two nibbles:

startup_timeout: uint4
collection_period: uint4
  • startup_timeout is a delay (0-150 seconds) between startup events (MCU boot and device configuration) and data collection in 10 second increments.
  • collection_period is the data collection time (500-7500 ms) after the startup event. Setting to 0 configures continuous measurement.

License

MIT license

Author

This software was developed by Anthony Wertz.

About

Real-time MAX30101 photoplethysmograph viewer and configuration tool.