You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Is your feature request related to a problem? Please describe.
It would be handy to create automations based on the power status of the UPS.
Additionally, most UPS can provide energy data which can be fed in to the energy dashboard
Is your feature request related to a problem? Please describe.
It would be handy to create automations based on the power status of the UPS.
Additionally, most UPS can provide energy data which can be fed in to the energy dashboard
Describe the solution you'd like
upsc ups@localhost Init SSL without certificate database battery.capacity: 9.00 battery.charge: 100 battery.charge.low: 20 battery.charge.restart: 0 battery.charger.status: floating battery.energysave: no battery.energysave.delay: 300 battery.energysave.load: 5 battery.protection: yes battery.runtime: 3588 battery.type: PbAc battery.voltage: 41.3 battery.voltage.nominal: 36 device.mfr: EATON device.model: 5P 1550 device.serial: G117N35066 device.type: ups driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.synchronous: auto driver.version: 2.8.0 driver.version.data: MGE HID 1.46 driver.version.internal: 0.47 driver.version.usb: libusb-1.0.26 (API: 0x1000109) input.current: 0.80 input.frequency: 50.0 input.frequency.extended: no input.frequency.nominal: 50 input.sensitivity: normal input.transfer.boost.low: 184 input.transfer.high: 294 input.transfer.low: 160 input.transfer.trim.high: 265 input.voltage: 233.9 input.voltage.extended: no input.voltage.nominal: 230 outlet.1.autoswitch.charge.low: 0 outlet.1.delay.shutdown: 65535 outlet.1.delay.start: 3 outlet.1.desc: PowerShare Outlet 1 outlet.1.id: 1 outlet.1.status: on outlet.1.switchable: yes outlet.2.autoswitch.charge.low: 0 outlet.2.delay.shutdown: 65535 outlet.2.delay.start: 6 outlet.2.desc: PowerShare Outlet 2 outlet.2.id: 2 outlet.2.status: on outlet.2.switchable: yes outlet.desc: Main Outlet outlet.id: 0 outlet.switchable: no output.current: 0.70 output.frequency: 50.0 output.frequency.nominal: 50 output.powerfactor: 0.73 output.voltage: 233.9 output.voltage.nominal: 230 ups.beeper.status: disabled ups.delay.shutdown: 20 ups.delay.start: 30 ups.efficiency: 90 ups.firmware: 03.18.0035 ups.load: 11 ups.load.high: 105 ups.mfr: EATON ups.model: 5P 1550 ups.power: 164 ups.power.nominal: 1550 ups.productid: ffff ups.realpower: 121 ups.realpower.nominal: 1100 ups.serial: G117N35066 ups.shutdown: enabled ups.start.auto: yes ups.start.battery: yes ups.start.reboot: yes ups.status: OL CHRG ups.test.interval: 2592000 ups.test.result: Done and passed ups.timer.shutdown: -1 ups.timer.start: -1 ups.type: offline / line interactive ups.vendorid: 0463
Home Assistant:
attribution: Data provided by TrueNAS integration Enable: true State: RUNNING icon: mdi:cog friendly_name: TrueNAS Services ups
Describe alternatives you've considered
Dockerising NUT on Scale and connecting HA and the USB UPS to NUT inside Docker
Additional context
The text was updated successfully, but these errors were encountered: