Notifications
You must be signed in to change notification settings - Fork 0
/
hp.lua
125 lines (115 loc) · 5.89 KB
/
hp.lua
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
return {
on = {
devices = { 't_ext', 'H/C', 'Heatpump heating' },
variables = { 'hd_ki', 'hd_lr', 'hs_ki', 'hs_lr' }
},
execute = function(dz, item)
t_ext = dz.devices('t_ext')
hco = dz.devices('H/C')
hpc = dz.devices('Heatpump cooling')
hph = dz.devices('Heatpump heating')
slope = 0.5
-- dz.log('@@@ devices(heat_slope).sensorValue ' .. dz.devices('heat_slope').sensorValue)
if dz.variables('hph_delayed_off').value ~= 0 and (dz.variables('hph_delayed_off').lastUpdate.minutesAgo > dz.variables('hph_delayed_off').value or hph.state == 'Off') then
dz.log('@@@ hph_delayed_off set 0 @@@')
dz.variables('hph_delayed_off').set(0)
end
if dz.variables('hph_delayed_on').value ~= 0 and (dz.variables('hph_delayed_on').lastUpdate.minutesAgo > 5 or hph.state == 'On') then
dz.log('@@@ hph_delayed_on set 0 @@@')
dz.variables('hph_delayed_on').set(0)
end
if hco.state == 'Cooling' then
if hph.state == 'On' then
if hph.lastUpdate.minutesAgo > 45 then
hph.switchOff()
end
end
elseif hco.state == 'Heating' then
if hpc.state == 'On' then
if hpc.lastUpdate.minutesAgo > 45 then
hpc.switchOff()
end
else
if dz.variables('hd_ki').value ~= 0 or dz.variables('hd_lr').value ~= 0 then
-- Determine heatslope to send to heatpump
-- hs = 0
-- if dz.variables('hd_ki').value ~= 0 and hs < dz.variables('hs_ki').value then
-- hs = dz.variables('hs_ki').value
-- end
-- if dz.variables('hd_lr').value ~= 0 and hs < dz.variables('hs_lr').value then
-- hs = dz.variables('hs_lr').value
-- end
-- if hs ~= 0 and hs ~= dz.devices('heat_slope').sensorValue then
-- dz.log('@@@ hs ' .. hs)
-- dz.log('@@@ dz.devices(heat_slope).sensorValue ' .. dz.devices('heat_slope').sensorValue)
-- dz.devices('heat_slope').updateCustomSensor(hs)
-- end
-- temporary, to manually set heat slope
-- if dz.devices('heat_slope').sensorValue ~= 0.55 then
-- dz.log('@@@ dz.devices(heat_slope) 0.55')
-- dz.devices('heat_slope').updateCustomSensor(0.55)
-- end
-- if dz.devices('heat_slope').sensorValue ~= slope then
-- dz.log('@@@ dz.devices(heat_slope)' .. slope)
-- dz.devices('heat_slope').updateCustomSensor(slope)
-- end
-- Determine setpoint to send to heatpump
sp_room = 0
if dz.variables('hd_ki').value ~= 0 and sp_room < dz.devices('H Kitchen').setPoint then
sp_room = dz.devices('H Kitchen').setPoint
end
if dz.variables('hd_lr').value ~= 0 and sp_room < dz.devices('H Livingroom').setPoint then
sp_room = dz.devices('H Livingroom').setPoint
end
if sp_room ~= 0 and sp_room ~= dz.devices('t_room1_setpoint').setPoint then
dz.log('@@@ sp_room ' .. sp_room)
dz.log('@@@ dz.devices(t_room1_setpoint).setPoint ' .. dz.devices('t_room1_setpoint').setPoint)
dz.devices('t_room1_setpoint').updateSetPoint(sp_room)
end
--
if dz.variables('hph_delayed_on').value == 0 and hph.state == 'Off' then
if t_ext.temperature < 2.1 then
dz.log('@@@ hph.switchOn() @@@')
hph.switchOn()
else
dz.log('@@@ hph_delayed_on set 1 @@@')
dz.variables('hph_delayed_on').set(1)
dz.log('@@@ hph.switchOn().afterMin(4) @@@')
hph.switchOn().afterMin(4)
end
end
if dz.variables('hph_delayed_off').value ~= 0 and hph.state == 'On' then
dz.log('@@@ hph_delayed_off set 0 @@@')
dz.variables('hph_delayed_off').set(0)
dz.log('@@@ hph.switchOn() @@@')
hph.switchOn()
end
else
if hph.state == 'On' and hph.lastUpdate.minutesAgo < 45 and dz.variables('hph_delayed_off').value == 0 then
dz.log('@@@ hph_delayed_off set 1 @@@')
dz.variables('hph_delayed_off').set(45 - hph.lastUpdate.minutesAgo)
dz.log('@@@ hph.switchOff 1 @@@')
-- dz.log('@@@ hph.switchOff 1 ' 45 - hph.lastUpdate.minutesAgo ' @@@')
hph.switchOff().afterMin(45 - hph.lastUpdate.minutesAgo)
end
if hph.state == 'On' and hph.lastUpdate.minutesAgo >= 45 then
dz.log('@@@ hph.switchOff 2 @@@')
hph.switchOff()
end
end
end
elseif hco.state == 'Off' then
if hpc.state == 'On' and hpc.lastUpdate.minutesAgo > 45 then
hpc.switchOff()
elseif hph.state == 'On' and hph.lastUpdate.minutesAgo > 45 then
hph.switchOff()
end
elseif hco.state == 'Manual' then
dz.log('hpc.state manual')
end
-- dz.log('@@@ hp dz.variables hd_ki value ' .. dz.variables('hd_ki').value)
-- dz.log('@@@ hp dz.variables hd_lr value ' .. dz.variables('hd_lr').value)
-- dz.log('@@@ hp dz.variables.hph_delayed_off ' .. dz.variables('hph_delayed_off').value)
-- dz.log('@@@ hp dz.variables.hph_delayed_on ' .. dz.variables('hph_delayed_on').value)
end
}