Notifications
You must be signed in to change notification settings - Fork 2
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. Weβll occasionally send you account related emails.
Already on GitHub? Sign in to your account
iCubGenova09 (iRonCub3) S/N:000 β Chest IMU cable pulled out from sleeve and probably disconnected #1689
Comments
|
Hi @gabrielenava , is the connector (cod.17372) damaged? |
the connector seems ok I think it is just the cable |
ciao @gabrielenava ho ripristinato il filo nero strappato e la schermatura del cavo che era saldata sul manicotto del connettore. Vi chiedo solamente di fare attenzione nello sconnettere il connettore dalla IMU facendo forza dove indicato dalla freccia e NON sul cavo per evitare di danneggiare il cavo. |
grazie mille! lo testiamo appena possibile poi possiamo chiudere il ticket |
Ciao @gabrielenava, Have you tested the IMU? I guess that is working now, isn't it? :) |
ciao @sgiraz not yet, but there are some tests scheduled for tomorrow and I can verify the IMU |
I have tested the robot in these days and the IMU is working fine! thanks again! we can close the issue |
Robot Name π€
iCubGenova09 (iRonCub3) S/N:000
Request/Failure description
The cable of the chest IMU pulled out of the sleeve during experiments with iRonCub, close to the connection with the chest IMU. The cables inside do not look disconnected or broken, nevertheless the IMU does not start anymore. We created a workaround with another (external) cable and the IMU is working fine, so we suspect that the cable not only exited the sleeve but also got damaged somehow.
Detailed context
Additional context
No response
How does it affect you?
No response
The text was updated successfully, but these errors were encountered: