iCubGenova09 (iRonCub3) S/N:000 β Xavier board (10.0.0.3) not reachable #1659
Comments
@gabrielenava concerning
As @S-Dafarra was mentioning F2F, this behaviour is similar to the problem we had while preparing for the ANA Avatar XPRIZE, see https://github.com/ami-iit/component_ANA-Avatar-XPRIZE/issues/767#issuecomment-1317267421 - @S-Dafarra do not hesitate to add more precise pointers So I wonder if we are using an image with the bridge still active, or with some old configuration @davidelasagna ? Concerning
Do not know. It is also true that if we do not use the XAVIER, we might physically disconnect it from the head |
The bridge is not active, the two boards have their own wireless interface, anyway I could check the configurations on the boards |
there is also this ticket @maggia80 @DanielePucci @Fabrizio69 the xavier to me can be even removed from the robot. the point was if it is possible to check if there are problems in the power supply of the head boards, because we lost both the Xavier and the COM-Express in few days and there might be something wrong with the power. |
re-tested today, I confirm we cannot reach the Xavier anymore. This is not blocking us for the moment. |
@davidelasagna this is the ticket we were mentioning today |
with @davidelasagna we tried to connect to the Xavier board, and it was working this time! I don't know what changed with respect to the previous tests. Meanwhile we opened the head to debug issues with the COM-Express, it is possible that a cable was not connected properly, and while checking all connections before closing the head to be sure we did not make mistakes it is possible we also fixed the Xavier cables. But I am not sure this is the reason. I think we can close the issue, if new problems with the Xavier emerge I can open a new one! |
Thanks for the feedback @gabrielenava. |
hello everyone, I reopen this issue to comment that the problem happened again, but with the help of @davidelasagna we spotted the cause: it is this power cable in the robot head: if you move it while the board is on, it shuts down. Probably it is damaged inside and when moving there is a short circuit. At the moment we use only the |
As discussed F2F, to solve this issue, we are ready to remove the NVIDIA Jetson Xavier NX from @gabrielenava are you agree? cc @DanielePucci @maggia80 @davidelasagna @AntonioConsilvio @Gandoo @Fabrizio69 |
I agree, at the moment we are not using the NX on iRonCub3 and we are not planning to use it. On the other hand, it is not the first time we have issues with this board, and this became riskier now because we are using the Ethernet connection that passes through the NX to communicate with the COM-Express. If there is an issue with the NX, we might loose control of the robot during flight experiments |
ciao @gabrielenava sul robot Γ¨ stato tolto il materiale richiesto, ho messo tutto in una scatola almeno la tenete voi. cc @DanielePucci @maggia80 @davidelasagna @AntonioConsilvio @sgiraz @Fabrizio69 |
Hi @gabrielenava, We are waiting for your feedback, then we'll proceed to close this issue. |
hello @sgiraz I have tested the robot today, I did not have any issue and the robot worked fine for the whole day. I think we can close the issue, thank you! |
Robot Name π€
iCubGenova09 (iRonCub3) S/N:000
Request/Failure description
we cannot ping or ssh the Xavier board.
cc @davidegorbani @DanielePucci
Detailed context
While preparing for the iRonCub experiments, we noted that the COM-Express board (NOT the Xavier) suddenly stop replying and it was not possible to ping or ssh it. After few minutes and without doing anything, the COM-Express came back and behaved normally. This strange behavior happened a couple of times, then never happened anymore.
While debugging the problem, we noted that the blue light of the wifi antenna of the Xavier was off. On the board, there was a green light. We tried to ping or ssh the Xavier but we did not gent any reply from the board. Differently from the COM-Express, this behavior was permanent: we were not able to ping or shh the Xavier for the rest of the experiment despite we also switched on/off the robot several times.
I am reporting also the COM-Express strange behavior because I don't know if it is related to the loss of communication with the Xavier. Also it is the second time in few days that a board in the iCub3 head has a failure: #1643