Monitors Ubiquiti device parameters, such as Ethernet, Radio and virtual access
point interfaces, exposed by the
UBNT-UniFi-MIB
and
UBNT-MIB
via SNMPv2.
This template is part of RaBe's Zabbix template and helpers collection.
- Download the
UBNT-UniFi-MIB
andUBNT-MIB
. - Place the MIB file(s) into your default MIB directory on the Zabbix server
and/or proxy (usually
/usr/local/share/snmp/mibs
) and make sure that the Zabbix server and/or proxy loads them (see Using and loading MIBs). - Import the
Template_SNMPv2_UBNT-UniFi-MIB.xml
into your Zabbix server (click on theRaw
button to download). - Add an SNMP interface configuration to your host
- Set the
{$SNMP_COMMUNITY}
macro to your desired community if you don't usepublic
- Add the template to your host (or stack template)
- Check if new data arrives
The following snmpwalk
command might be helpful for debugging:
snmpwalk -v 2c -c public <HOST> UBNT-MIB::ubnt
SNMPv2 template for monitoring Ubiquiti devices exposing UBNT-UniFi-MIB
(The UniFi MIB module for Ubiquiti Networks, Inc.) entities.
- IP address of access point (
rabe.snmp.ubnt-unifi-mib.unifiApSystemIp[]
)
The IP address of the access point. - Model of access point (
rabe.snmp.ubnt-unifi-mib.unifiApSystemModel[]
)
The model of the access point. - Uptime of access point (
rabe.snmp.ubnt-unifi-mib.unifiApSystemUptime[]
)
The uptime of the access point. - Version of access point (
rabe.snmp.ubnt-unifi-mib.unifiApSystemVersion[]
)
The firmware version of the access point.
{$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_HIGH_PERCENTAGE}
(default: 90){$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_HIGH_TIME}
(default: 30m){$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_WARNING_PERCENTAGE}
(default: 80){$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_WARNING_TIME}
(default: 15m){$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_HIGH_PERCENTAGE}
(default: 90){$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_HIGH_TIME}
(default: 30m){$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_WARNING_PERCENTAGE}
(default: 80){$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_WARNING_TIME}
(default: 15m){$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_HIGH_PERCENTAGE}
(default: 95){$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_HIGH_TIME}
(default: 30m){$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_WARNING_PERCENTAGE}
(default: 85){$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_WARNING_TIME}
(default: 30m){$SNMPV2_UBNT_UNIFI_MIB_VAP_IF_CONNECTED_STATIONS_HIGH_THRESHOLD}
(default: 70){$SNMPV2_UBNT_UNIFI_MIB_VAP_IF_CONNECTED_STATIONS_WARNING_THRESHOLD}
(default: 50)
Discovery of Ethernet interfaces
Returns the following macro for each available Ethernet interface (UbntIfEntry
)
{#IF_NAME}
- The name of each discovered Ethernet interface (
UBNT-UniFi-MIB::unifiIfName
).
- The name of each discovered Ethernet interface (
- IP address of Ethernet interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiIfIp[{#IF_NAME}]
)
The IP address of the Ethernet interface. - MAC address of Ethernet interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiIfMac[{#IF_NAME}]
)
The MAC address of the Ethernet interface. - Inbound traffic on Ethernet interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiIfRxBytes[{#IF_NAME}]
)
Received bits per second on the Ethernet interface. - Inbound packets dropped on Ethernet interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiIfRxDropped[{#IF_NAME}]
)
Inbound dropped packets per second on the Ethernet interface. - Inbound errors on Ethernet interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiIfRxError[{#IF_NAME}]
)
Inbound errors per second on the Ethernet interface. - Inbound packets on Ethernet interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiIfRxPackets[{#IF_NAME}]
)
Inbound packets per second on the Ethernet interface. - Speed of Ethernet interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiIfSpeed[{#IF_NAME}]
)
Speed of the Ethernet interface. - Outbound traffic on Ethernet interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiIfTxBytes[{#IF_NAME}]
)
Transmitted bits per second on the Ethernet interface. - Outbound packets dropped on Ethernet interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiIfTxDropped[{#IF_NAME}]
)
Outbound dropped packets per second on the Ethernet interface. - Outbound errors on Ethernet interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiIfTxError[{#IF_NAME}]
)
Outbound errors per second on the Ethernet interface. - Outbound packets on Ethernet interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiIfTxPackets[{#IF_NAME}]
)
Outbound packets per second on the Ethernet interface. - Up status of Ethernet interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiIfUp[{#IF_NAME}]
)
The up status of the Ethernet interface.
- Warning: Inbound utilization is high (> $2 % over {$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_WARNING_TIME:"{#IF_NAME}"}) on {HOST.NAME} interface {#IF_NAME}
The inbound average interface utilization is higher than the configured percent value (
{Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiIfRxBytes[{#IF_NAME}].avg({$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_WARNING_TIME:"{#IF_NAME}"})} > {Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiIfSpeed[{#IF_NAME}].last()} / 100 * {$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_WARNING_PERCENTAGE:"{#IF_NAME}"}
{$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_WARNING_PERCENTAGE:"{#IF_NAME}"}
) of the maximum interface speed over the configured amount of time ({$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_WARNING_TIME:"{#IF_NAME}"}
). - High: Inbound utilization is very high (> $2 % over {$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_HIGH_TIME:"{#IF_NAME}"}) on {HOST.NAME} interface {#IF_NAME}
The inbound average interface utilization is higher than the configured percent value (
{Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiIfRxBytes[{#IF_NAME}].avg({$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_HIGH_TIME:"{#IF_NAME}"})} > {Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiIfSpeed[{#IF_NAME}].last()} / 100 * {$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_HIGH_PERCENTAGE:"{#IF_NAME}"}
{$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_HIGH_PERCENTAGE:"{#IF_NAME}"}
) of the maximum interface speed over the configured amount of time ({$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_IN_UTILIZATION_HIGH_TIME:"{#IF_NAME}"}
). - High: Interface status is down on {HOST.NAME} interface {#IF_NAME}
The Ethernet interface is down.
{Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiIfUp[{#IF_NAME}].last()}<>1
- Warning: Outbound utilization is high (> $2 % over {$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_WARNING_TIME:"{#IF_NAME}"}) on {HOST.NAME} interface {#IF_NAME}
The outbound average interface utilization is higher than the configured percent value (
{Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiIfTxBytes[{#IF_NAME}].avg({$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_WARNING_TIME:"{#IF_NAME}"})} > {Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiIfSpeed[{#IF_NAME}].last()} / 100 * {$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_WARNING_PERCENTAGE:"{#IF_NAME}"}
{$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_WARNING_PERCENTAGE:"{#IF_NAME}"}
) of the maximum interface speed over the configured amount of time ({$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_WARNING_TIME:"{#IF_NAME}"}
). - High: Outbound utilization is very high (> $2 % over {$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_HIGH_TIME:"{#IF_NAME}"}) on {HOST.NAME} interface {#IF_NAME}
The outbound average interface utilization is higher than the configured percent value (
{Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiIfTxBytes[{#IF_NAME}].avg({$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_HIGH_TIME:"{#IF_NAME}"})} > {Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiIfSpeed[{#IF_NAME}].last()} / 100 * {$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_HIGH_PERCENTAGE:"{#IF_NAME}"}
{$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_HIGH_PERCENTAGE:"{#IF_NAME}"}
) of the maximum interface speed over the configured amount of time ({$SNMPV2_UBNT_UNIFI_MIB_ETH_IF_OUT_UTILIZATION_HIGH_TIME:"{#IF_NAME}"}
).
Discovery of radio interfaces.
Returns the following macro for each available radio interface (unifiRadioEntry
)
{#RADIO_NAME}
- The name of each discovered radio interface (
UBNT-UniFi-MIB::unifiRadioName
).
- The name of each discovered radio interface (
- Channel utilization self receive on radio interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiRadioCuSelfRx[{#RADIO_NAME}]
)
The self receive channel utilization on the radio interface in percent. - Channel utilization self transmit on radio interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiRadioCuSelfTx[{#RADIO_NAME}]
)
The self transmit channel utilization on the radio interface in percent. - Channel utilization total on radio interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiRadioCuTotal[{#RADIO_NAME}]
)
The total channel utilization on the radio interface in percent. - Mode of radio interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiRadioRadio[{#RADIO_NAME}]
)
The radio interface's mode. - Received packets on radio interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiRadioRxPackets[{#RADIO_NAME}]
)
The number of received packets on the radio interface per second. - Transmitted packets on radio interface $1 (
rabe.snmp.ubnt-unifi-mib.unifiRadioTxPackets[{#RADIO_NAME}]
)
The number of transmitted packets on the radio interface per second.
- Warning: Total channel utilization is high (> $1% over {$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_WARNING_TIME:"{#RADIO_NAME}"}) on {HOST.NAME} radio interface {#RADIO_NAME}
The total average channel utilization of the radio interface is higher than the configured percent value (
{Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiRadioCuTotal[{#RADIO_NAME}].avg({$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_WARNING_TIME:"{#RADIO_NAME}"})} > {$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_WARNING_PERCENTAGE:"{#RADIO_NAME}"}
{$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_WARNING_PERCENTAGE:"{#RADIO_NAME}"}
) over the configured amount of time ({$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_WARNING_TIME:"{#RADIO_NAME}"}
). - High: Total channel utilization is very high ( > $1% over {$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_HIGH_TIME:"{#RADIO_NAME}"}) on {HOST.NAME} radio interface {#RADIO_NAME}
The total average channel utilization of the radio interface is higher than the configured percent value (
{Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiRadioCuTotal[{#RADIO_NAME}].avg({$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_HIGH_TIME:"{#RADIO_NAME}"})} > {$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_HIGH_PERCENTAGE:"{#RADIO_NAME}"}
{$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_HIGH_PERCENTAGE:"{#RADIO_NAME}"}
) over the configured amount of time ({$SNMPV2_UBNT_UNIFI_MIB_RADIO_IF_TOTAL_UTILIZATION_HIGH_TIME:"{#RADIO_NAME}"}
).
Discovery of virtual access point interfaces
Returns the following macros for each available virtual access point interface (unifiVapEntry
)
{#VAP_NAME}
- The name of each discovered virtual access point interface (
UBNT-UniFi-MIB::unifiVapName
).
- The name of each discovered virtual access point interface (
{#VAP_ESSID}
- The (current) Extended Service Set (ESS) ID of each discovered virtual access point interface (
UBNT-UniFi-MIB::unifiVapEssId
).
- The (current) Extended Service Set (ESS) ID of each discovered virtual access point interface (
- BSS ID of virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapBssId[{#VAP_NAME}]
)
The Basic Service Set (BSS) ID of the virtual access point. - Channel of virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapChannel[{#VAP_NAME}]
)
The channel of the virtual access point. - ESS ID of virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapEssId[{#VAP_NAME}]
)
The Extended Service Set (ESS) ID of the virtual access point. - Number of connected stations on access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapNumStations[{#VAP_NAME}]
)
The number of connected stations on this virtual access point. - Inbound traffic on virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapRxBytes[{#VAP_NAME}]
)
Received bits per second on the virtual access point. - Inbound packets dropped on virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapRxDropped[{#VAP_NAME}]
)
Inbound dropped packets per second on the virtual access point. - Inbound errors on virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapRxErrors[{#VAP_NAME}]
)
Inbound errors per second on the virtual access point. - Inbound packets on virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapRxPackets[{#VAP_NAME}]
)
Inbound packets per second on the virtual access point. - Inbound retries on virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapRxRetries[{#VAP_NAME}]
)
Inbound retries per second on the virtual access point. - Outbound traffic on virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapTxBytes[{#VAP_NAME}]
)
Transmitted bits per second on the virtual access point. - Outbound packets dropped on virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapTxDropped[{#VAP_NAME}]
)
Outbound dropped packets per second on the virtual access point. - Outbound errors on virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapTxErrors[{#VAP_NAME}]
)
Outbound errors per second on the virtual access point. - Outbound packets on virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapTxPackets[{#VAP_NAME}]
)
Outbound packets per second on the virtual access point. - Outbound retries on virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapTxRetries[{#VAP_NAME}]
)
Outbound retries per second on the virtual access point. - Up status of virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapUp[{#VAP_NAME}]
)
The up status of the virtual access point. - Usage type of virtual access point $1 (
rabe.snmp.ubnt-unifi-mib.unifiVapUsage[{#VAP_NAME}]
)
The usage type of the virtual access point.
- Warning: Many stations (> $1) connected to virtual access point on {HOST.NAME} interface {#VAP_NAME} ({#VAP_ESSID})
There are many stations (>
{Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiVapNumStations[{#VAP_NAME}].last()} >= {$SNMPV2_UBNT_UNIFI_MIB_VAP_IF_CONNECTED_STATIONS_WARNING_THRESHOLD:"{#VAP_NAME}"}
{$SNMPV2_UBNT_UNIFI_MIB_VAP_IF_CONNECTED_STATIONS_WARNING_THRESHOLD:"{#VAP_NAME}"}
) connected to the virtual access point. - High: Too many stations (> $1) connected to virtual access point on {HOST.NAME} interface {#VAP_NAME} ({#VAP_ESSID})
There are too many stations (>
{Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiVapNumStations[{#VAP_NAME}].last()} >= {$SNMPV2_UBNT_UNIFI_MIB_VAP_IF_CONNECTED_STATIONS_HIGH_THRESHOLD:"{#VAP_NAME}"}
{$SNMPV2_UBNT_UNIFI_MIB_VAP_IF_CONNECTED_STATIONS_HIGH_THRESHOLD:"{#VAP_NAME}"}
) connected to the virtual access point. - Information: Virtual access point ESS ID name was changed on {HOST.NAME} interface {#VAP_NAME} ({#VAP_ESSID})
The ESS ID of the virtual access point was changed.
{Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiVapEssId[{#VAP_NAME}].diff()}=1
- High: Virtual access point status is down on {HOST.NAME} interface {#VAP_NAME} ({#VAP_ESSID})
The virtual access point interface is down.
{Template SNMPv2 UBNT-UniFi-MIB:rabe.snmp.ubnt-unifi-mib.unifiVapUp[{#VAP_NAME}].last()}<>1
This template is free software: you can redistribute it and/or modify it under the terms of the GNU Affero General Public License as published by the Free Software Foundation, version 3 of the License.
Copyright (c) 2017 - 2020 Radio Bern RaBe