mPower 3 Outlet subs wrong #9

Open
dersch81 opened this issue Dec 27, 2018 · 3 comments
Open

mPower 3 Outlet subs wrong #9

dersch81 opened this issue Dec 27, 2018 · 3 comments

Comments

@dersch81
Copy link

Hi, first of all it is working very easy! Thanks for your great work!

I have 2 devices mPower Mini and 3 Port Outlet.

With the Mini i have all subs as expected, voltage, power, energy everything is fine.

But with the 3 Port mPower i don't have any energy value it is always 0 for all ports.

@magcode
Copy link
Owner

magcode commented Dec 28, 2018

Hi,

can you check the output of

cat /proc/power/enabled1

In case it returns 0 please do the following:
echo 1 > /proc/power/enabled1

Then try again (plug in a device on port 1 and check in MQTT)

If that works now do the same for the other ports (enabled2 ... enabled3)

@dersch81
Copy link
Author

Yes that was the case. Now i get the energy value via MQTT. Thanks

@magcode
Copy link
Owner

magcode commented Dec 31, 2018

Thanks for feedback. I'll either add this to the documentation or maybe add some scripting to enable it automatically.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment