Hi, first of all it is working very easy! Thanks for your great work!
I have 2 devices mPower Mini and 3 Port Outlet.
With the Mini i have all subs as expected, voltage, power, energy everything is fine.
But with the 3 Port mPower i don't have any energy value it is always 0 for all ports.
The text was updated successfully, but these errors were encountered:
Hi,
can you check the output of
cat /proc/power/enabled1
In case it returns 0 please do the following: echo 1 > /proc/power/enabled1
0
echo 1 > /proc/power/enabled1
Then try again (plug in a device on port 1 and check in MQTT)
If that works now do the same for the other ports (enabled2 ... enabled3)
Sorry, something went wrong.
Yes that was the case. Now i get the energy value via MQTT. Thanks
Thanks for feedback. I'll either add this to the documentation or maybe add some scripting to enable it automatically.
No branches or pull requests
Hi, first of all it is working very easy! Thanks for your great work!
I have 2 devices mPower Mini and 3 Port Outlet.
With the Mini i have all subs as expected, voltage, power, energy everything is fine.
But with the 3 Port mPower i don't have any energy value it is always 0 for all ports.
The text was updated successfully, but these errors were encountered: