a2o_flux can not be automatically created after the first model year (cold start)
The text was updated successfully, but these errors were encountered:
on both ollie and mistral
Sorry, something went wrong.
@xshi-awi maybe related to this #195 When I run the tidy job, NCO has not been loaded. When I loaded it manually before running tidy it worked for me.
tidy
ncwa works fine. Here is the err info: cdo -O merge o2a_flux_recv
cdo (Abort): Input streams missing! rm onlyonetimestep.nc
The log file: /home/ollie/xshi/work/AWIESM_2_1_LR_concurrent_rad/lgm_m1_beta/scripts/lgm_m1_beta_compute_20020101-20021231_12510014.log