-
Notifications
You must be signed in to change notification settings - Fork 20
/
LogViewer.Receivers.ComPort.Settings.pas
218 lines (178 loc) · 4.71 KB
/
LogViewer.Receivers.ComPort.Settings.pas
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
{
Copyright (C) 2013-2022 Tim Sinaeve [email protected]
Licensed under the Apache License, Version 2.0 (the "License");
you may not use this file except in compliance with the License.
You may obtain a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS,
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
See the License for the specific language governing permissions and
limitations under the License.
}
unit LogViewer.Receivers.ComPort.Settings;
{ Persistable settings for ComPort subscriber. }
interface
uses
System.Classes,
Spring;
type
TComPortSettings = class(TPersistent)
const
//DEFAULT_BAUDRATE = 9600;
DEFAULT_BAUDRATE = 115200;
DEFAULT_POLLING_INTERVAL = 50;
private
FBaudRate : Integer;
FDataBits : Integer;
FStopBits : Integer;
FParity : Char;
FPort : string;
FPollingInterval : Integer;
FOnChanged : Event<TNotifyEvent>;
{$REGION 'property access methods'}
function GetBaudRate: Integer;
procedure SetBaudRate(const Value: Integer);
function GetPort: string;
procedure SetPort(const Value: string);
function GetOnChanged: IEvent<TNotifyEvent>;
function GetPollingInterval: Integer;
procedure SetPollingInterval(const Value: Integer);
function GetDataBits: Integer;
procedure SetDataBits(const Value: Integer);
function GetStopBits: Integer;
procedure SetStopBits(const Value: Integer);
function GetParity: Char;
procedure SetParity(const Value: Char);
{$ENDREGION}
protected
procedure Changed;
public
procedure AfterConstruction; override;
procedure Assign(Source: TPersistent); override;
property BaudRate: Integer
read GetBaudRate write SetBaudRate default DEFAULT_BAUDRATE;
property DataBits: Integer
read GetDataBits write SetDataBits;
property StopBits: Integer
read GetStopBits write SetStopBits;
property Parity: Char
read GetParity write SetParity;
property Port: string
read GetPort write SetPort;
property PollingInterval: Integer // in ms
read GetPollingInterval write SetPollingInterval
default DEFAULT_POLLING_INTERVAL;
property OnChanged: IEvent<TNotifyEvent>
read GetOnChanged;
end;
implementation
{$REGION 'construction and destruction'}
procedure TComPortSettings.AfterConstruction;
begin
inherited AfterConstruction;
FBaudRate := DEFAULT_BAUDRATE;
FPollingInterval := DEFAULT_POLLING_INTERVAL;
end;
{$ENDREGION}
{$REGION 'property access methods'}
function TComPortSettings.GetBaudRate: Integer;
begin
Result := FBaudRate;
end;
procedure TComPortSettings.SetBaudRate(const Value: Integer);
begin
if Value <> BaudRate then
begin
FBaudRate := Value;
Changed;
end;
end;
function TComPortSettings.GetDataBits: Integer;
begin
Result := FDataBits;
end;
procedure TComPortSettings.SetDataBits(const Value: Integer);
begin
if Value <> DataBits then
begin
FDataBits := Value;
Changed;
end;
end;
function TComPortSettings.GetOnChanged: IEvent<TNotifyEvent>;
begin
Result := FOnChanged;
end;
function TComPortSettings.GetPollingInterval: Integer;
begin
Result := FPollingInterval;
end;
function TComPortSettings.GetParity: Char;
begin
Result := FParity;
end;
procedure TComPortSettings.SetParity(const Value: Char);
begin
if Value <> Parity then
begin
FParity := Value;
Changed;
end;
end;
procedure TComPortSettings.SetPollingInterval(const Value: Integer);
begin
if Value <> PollingInterval then
begin
FPollingInterval := Value;
Changed;
end;
end;
function TComPortSettings.GetPort: string;
begin
Result := FPort;
end;
procedure TComPortSettings.SetPort(const Value: string);
begin
if Value <> Port then
begin
FPort := Value;
Changed;
end;
end;
function TComPortSettings.GetStopBits: Integer;
begin
Result := FStopBits;
end;
procedure TComPortSettings.SetStopBits(const Value: Integer);
begin
if Value <> StopBits then
begin
FStopBits := Value;
Changed;
end;
end;
{$ENDREGION}
{$REGION 'event dispatch methods'}
procedure TComPortSettings.Changed;
begin
FOnChanged.Invoke(Self);
end;
{$ENDREGION}
{$REGION 'protected methods'}
procedure TComPortSettings.Assign(Source: TPersistent);
var
CPS: TComPortSettings;
begin
if Source is TComPortSettings then
begin
CPS := TComPortSettings(Source);
FBaudRate := CPS.BaudRate;
FPort := CPS.Port;
FPollingInterval := CPS.PollingInterval;
end
else
inherited Assign(Source);
end;
{$ENDREGION}
end.