[chassis] Image upgrade on the 7808 chassis wipes out the configuration on the Linecards #105
Comments
add arista_logs |
add |
I ran this on one of our DUTs and was unable to reproduce the issue. Is this issue consistently reproducible on your end or has it only happened this once? |
As discussed offline the clearing of configuration files may a consequence of the PCIe errors seen on this particular supervisor. |
@kenneth-arista, can you please provide a root-cause why the linecard went to provision mode. |
@kenneth-arista - it seems due to this issue, this testbed in our lab cannot be used. What should be the fix for this? |
The 7808 chassis in the lab is being upgrading using the command
./testbed-cli.sh install-image vms26-t2-7800-1 str2 http://10.201.148.43/pipelines/Networking-acs-buildimage-Official/broadcom/internal-202405/sonic-aboot-broadcom-dnx.swi
vms26-t2-7800-1
is the T2 testbed with one supervisor and 3 Linecards (2 Clearwater2 cards and one wolverine card)str2
is the inventory file nameThis command upgrades the supervisor and all the linecards and waits for Linecards and supervisor to be up.
This commands errors out because the chassis is not accessible after 15 mins
On logging in from the serial port, I see these errors on the screen for long time
Eventually these backtraces are seen supervisor bootups
after this the linecards come up with the new image but the minigraph/config is not retained from the previous image
Looks like the linecards are provisioned again.