Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Changes for the calibration of the Youngs modulus calibration #169

Open
joergfunger opened this issue May 17, 2023 · 0 comments
Open

Changes for the calibration of the Youngs modulus calibration #169

joergfunger opened this issue May 17, 2023 · 0 comments

Comments

@joergfunger
Copy link
Member

  • the hardcoded 4*100 MCMC samples should be parameterized or at least tested, this is IMO much too small,
  • the usage of an old probeye version,
  • the fixed prior for the noise level for the displacements (0.005mm?, this seems to be way too small)
  • units are not used in the calibration part (leading the to ? in the above point)
    Potentially, this could be split in multiple issues once being worked on.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Projects
None yet
Development

No branches or pull requests

2 participants