Readout configuration parameters reference

This document describes all the configuration parameters that can be set in readout.

Some parameters control the behavior of readout as soon as it starts, and are valid for the lifetime of the process. (1)

Other parameters (2) are set whenever the control state-machine receives the CONFIGURE command (or shortly after startup when running o2-readout-exe outside from the ECS workflow, typically from the command line) and until the RESET command. The corresponding parameters usually come from a local file or from a central reposity, as provided by the O2 system. They can be reloaded several time during the lifetime of the process.

Readout defaults (1)

These are defined in local file /etc/o2.d/readout-default.cfg, which is loaded on o2-readout-exe startup (if the file exists). They are valid for the lifetime of the o2-readout-exe process. There is usually no need for users to edit these settings. The file format is '.ini' style, with [sections] and key=value pairs.

Following table describes the parameters of the [readout] section.

Parameter name Type Default value Description
memLock int 0 Defines the memory swapping policy. If set, all readout memory is locked in RAM with mlockall()
readoutExe string If set, overwrites the current running executable with the one at given path. Used for tests.
readoutConfig string If set with readoutExe, launch the new exe with this parameter as argument. Used for tests.
statsPublishAddress string If set, address where to publish readout stats, eg "tcp://127.0.0.1:6008" (o2-readout-monitor should listen there).
statsPublishInterval string If set, interval for readout stats publish, in seconds.
db string If set, defines connection parameters to a MySQL database in the form 'user:password@host/dbname'. Runtime statistics are stored in a table. Structure can be created with o2-readout-admin-db.
customCommandsEnabled int 0 If set, custom commands are enabled, i.e. launching external scripts at some specific state transitions. See customCommands keyword below.
membanksMonitorPath string Path to memory banks monitor output (a local file FIFO, to be connected with o2-readout-monitor-memory).
membanksMonitorRate double 0 Rate (in Hertz) at which to publish memory status.

Readout configuration file (2)

Sections

The readout configuration is split in different sections. Some sections have a unique instance (single name), some may have multiple instances (prefix-[instance name], shown as prefix-* in this document).

The readout section defines global parameters. The bank-* section defines parameters for the memory banks. The equipment-* section defines parameters for the readout equipments. The consumer-* section defines parameters for the readout data consumers. The receiverFMQ-* section defines parameters for the test receiverFMQ.exe program, and usually kept at the same place as readout parameters for coherency.

Please see the provided example configuration files to see how they are usually arranged.

It is possible to define some default parameters to be used in all matching sections by creating a section which name ends with "-*" and containing some key-value pairs. These pairs are applied to all sections with similar names. Existing key-value pairs are not overwritten, but are defined according to these defaults if they don't exist. It can be useful to create multiple equipments with similar settings.

Parameter types

The following table describes the types used in the configuration, giving:

  • Name: the name by which this type is referenced in this documentation.
  • Input: the type necessary to store the input value in the configuration system.
  • Output: the type used in readout, to make use of the value.
  • Notes: extra information on the type and conversion process, if applicable.
Name Input Output Notes
int int int
double double double
string string string
bytes string long long Input string is converted to a 64-bit integer value allowing usual "base units" in the suffix (k,M,G,T), as powers of 1024. Input can be decimal (1.5M is valid, will give 1.5*1024*1024).

Parameters description

Parameters without a default value are usually mandatory in the corresponding section. Some parameters may be set for all instances of a given section [sectionName-*], some may apply only to the instances of a given type [sectionName-type-*]. The parameters related to 3rd-party libraries are described here for convenience, but should be further checked in the corresponding source documentation. In particular, please refer to:

Section Parameter name Type Default value Description
bank-* enabled int 1 Enable (1) or disable (0) the memory bank.
bank-* numaNode int -1 Numa node where memory should be allocated. -1 means unspecified (system will choose).
bank-* size bytes Size of the memory bank, in bytes.
bank-* type string Support used to allocate memory. Possible values: malloc, MemoryMappedFile.
consumer-* consumerOutput string Name of the consumer where the output of this consumer (if any) should be pushed.
consumer-* consumerType string The type of consumer to be instanciated. One of:stats, FairMQDevice, DataSampling, FairMQChannel, fileRecorder, checker, processor, tcp.
consumer-* enabled int 1 Enable (value=1) or disable (value=0) the consumer.
consumer-* filterEquipmentIdsExclude string Defines a filter based on equipment ids. All data belonging to the equipments in this list (coma separated values) are rejected.
consumer-* filterEquipmentIdsInclude string Defines a filter based on equipment ids. Only data belonging to the equipments in this list (coma separated values) are accepted. If empty, all equipment ids are fine.
consumer-* filterLinksExclude string Defines a filter based on link ids. All data belonging to the links in this list (coma separated values) are rejected.
consumer-* filterLinksInclude string Defines a filter based on link ids. Only data belonging to the links in this list (coma separated values) are accepted. If empty, all link ids are fine.
consumer-* name string Name used to identify this consumer (in logs). By default, it takes the name of the configuration section, consumer-xxx
consumer-* numaNode int -1 If set (>=0), memory / thread will try to use given NUMA node.
consumer-* stopOnError int 0 If 1, readout will stop automatically on consumer error.
consumer-data-sampling-* address string ipc:///tmp/readout-pipe-1 Address of the data sampling.
consumer-FairMQChannel-* checkIncomplete int 0 If set, readout checks for the completeness of HBF and issues warnings. Set automatically when dropIncomplete=1.
consumer-FairMQChannel-* checkResources string Check beforehand if unmanaged region would fit in given list of resources. Comma-separated list of items to be checked: eg /dev/shm, MemFree, MemAvailable. (any filesystem path, and any /proc/meminfo entry).
consumer-FairMQChannel-* disableSending int 0 If set, no data is output to FMQ channel. Used for performance test to create FMQ shared memory segment without pushing the data.
consumer-FairMQChannel-* dropIncomplete int 0 If set, TF with incomplete HBF (i.e. HBF having missing packets) are discarded.
consumer-FairMQChannel-* enablePackedCopy int 1 If set, the same superpage may be reused (space allowing) for the copy of multiple HBF (instead of a separate one for each copy). This allows a reduced memoryPoolNumberOfPages.
consumer-FairMQChannel-* enableRawFormat int 0 If 0, data is pushed 1 STF header + 1 part per HBF. If 1, data is pushed in raw format without STF headers, 1 FMQ message per data page. If 2, format is 1 STF header + 1 part per data page.
consumer-FairMQChannel-* fmq-address string ipc:///tmp/pipe-readout Address of the FMQ channel. Depends on transportType. c.f. FairMQ::FairMQChannel.h
consumer-FairMQChannel-* fmq-name string readout Name of the FMQ channel. c.f. FairMQ::FairMQChannel.h
consumer-FairMQChannel-* fmq-progOptions string Additional FMQ program options parameters, as a comma-separated list of key=value pairs.
consumer-FairMQChannel-* fmq-transport string shmem Name of the FMQ transport. Typically: zeromq or shmem. c.f. FairMQ::FairMQChannel.h
consumer-FairMQChannel-* fmq-type string pair Type of the FMQ channel. Typically: pair. c.f. FairMQ::FairMQChannel.h
consumer-FairMQChannel-* memoryBankName string Name of the memory bank to crete (if any) and use. This consumer has the special property of being able to provide memory banks to readout, as the ones defined in bank-*. It creates a memory region optimized for selected transport and to be used for readout device DMA.
consumer-FairMQChannel-* memoryPoolNumberOfPages int 100 c.f. same parameter in bank-*.
consumer-FairMQChannel-* memoryPoolPageSize bytes 128k c.f. same parameter in bank-*.
consumer-FairMQChannel-* sessionName string default Name of the FMQ session. c.f. FairMQ::FairMQChannel.h
consumer-FairMQChannel-* threads int 0 If set, a pool of threads is created for the data processing.
consumer-FairMQChannel-* threadsFifoSize int 0 Incoming FIFO size for processing threads. By default, value is guessed.
consumer-FairMQChannel-* unmanagedMemorySize bytes Size of the memory region to be created. c.f. FairMQ::FairMQUnmanagedRegion.h. If not set, no special FMQ memory region is created.
consumer-fileRecorder-* bytesMax bytes 0 Maximum number of bytes to write to each file. Data pages are never truncated, so if writing the full page would exceed this limit, no data from that page is written at all and file is closed. If zero (default), no maximum size set.
consumer-fileRecorder-* dataBlockHeaderEnabled int 0 Enable (1) or disable (0) the writing to file of the internal readout header (Readout DataBlock.h) between the data pages, to easily navigate through the file without RDH decoding. If disabled, the raw data pages received from CRU are written without further formatting.
consumer-fileRecorder-* dropEmptyHBFrames int 0 If 1, memory pages are scanned and empty HBframes are discarded, i.e. couples of packets which contain only RDH, the first one with pagesCounter=0 and the second with stop bit set. This setting does not change the content of in-memory data pages, other consumers would still get full data pages with empty packets. This setting is meant to reduce the amount of data recorded for continuous detectors in triggered mode. Use with dropEmptyHBFramesTriggerMask, if some empty frames with specific trigger types need to be kept (eg TF or SOC).
consumer-fileRecorder-* dropEmptyHBFramesTriggerMask int 0 (when using dropEmptyHBFrames = 1) empty HB frames are kept if any bit in RDH TriggerType field matches this pattern (RDHTriggerType & TriggerMask != 0). To be provided as a decimal value: eg 2048 (TF triggers, bit 11), 3584 (TF + SOC + EOC bits 9,10,11).
consumer-fileRecorder-* fileName string Path to the file where to record data. The following variables are replaced at runtime: ${XXX} -> get variable XXX from environment, %t -> unix timestamp (seconds since epoch), %T -> formatted date/time, %i -> equipment ID of each data chunk (used to write data from different equipments to different output files), %l -> link ID (used to write data from different links to different output files).
consumer-fileRecorder-* filesMax int 1 If 1 (default), file splitting is disabled: file is closed whenever a limit is reached on a given recording stream. Otherwise, file splitting is enabled: whenever the current file reaches a limit, it is closed an new one is created (with an incremental name). If = 0, an unlimited number of incremental chunks can be created. If smaller than zero, it defines the number of chunks to use round-robin, indefinitely. If bigger than zero, it defines the maximum number of chunks. The file name is suffixed with chunk number (by default, ".001, .002, ..." at the end of the file name. One may use "%f" in the file name to define where this incremental file counter is printed.
consumer-fileRecorder-* pagesMax int 0 Maximum number of data pages accepted by recorder. If zero (default), no maximum set.
consumer-fileRecorder-* tfMax int 0 Maximum number of timeframes accepted by recorder. If zero (default), no maximum set.
consumer-processor-* ensurePageOrder int 0 If set, ensures that data pages goes out of the processing pool in same order as input (which is not guaranteed with multithreading otherwise). This option adds latency.
consumer-processor-* libraryPath string Path to the library file providing the processBlock() function to be used.
consumer-processor-* numberOfThreads int 1 Number of threads running the processBlock() function in parallel.
consumer-processor-* threadIdleSleepTime int 1000 Sleep time (microseconds) of inactive thread, before polling for next data.
consumer-processor-* threadInputFifoSize int 10 Size of input FIFO, where pending data are waiting to be processed.
consumer-rdma-* host string localhost Remote server IP name to connect to.
consumer-rdma-* port int 10001 Remote server TCP port number to connect to.
consumer-stats-* consoleUpdate int 0 If non-zero, periodic updates also output on the log console (at rate defined in monitoringUpdatePeriod). If zero, periodic log output is disabled.
consumer-stats-* monitoringEnabled int 0 Enable (1) or disable (0) readout monitoring.
consumer-stats-* monitoringUpdatePeriod double 10 Period of readout monitoring updates, in seconds.
consumer-stats-* monitoringURI string URI to connect O2 monitoring service. c.f. o2::monitoring.
consumer-stats-* processMonitoringInterval int 0 Period of process monitoring updates (O2 standard metrics). If zero (default), disabled.
consumer-stats-* zmqPublishAddress string If defined, readout statistics are also published periodically (at rate defined in monitoringUpdatePeriod) to a ZMQ server. Suggested value: tcp://127.0.0.1:6008 (for use by o2-readout-monitor).
consumer-tcp-* host string localhost Remote server IP name to connect to.
consumer-tcp-* ncx int 1 Number of parallel streams (and threads) to use. The port number specified in 'port' parameter will be increased by 1 for each extra connection.
consumer-tcp-* port int 10001 Remote server TCP port number to connect to.
consumer-zmq-* address string tcp://127.0.0.1:50001 ZMQ address where to publish (PUB) data pages, eg ipc://@readout-eventDump
consumer-zmq-* maxRate int 0 Maximum number of pages to publish per second. The associated memory copy has an impact on cpu load, so this should be limited when one does not use all the data (eg for eventDump).
consumer-zmq-* pagesPerBurst int 1 Number of consecutive pages guaranteed to be part of each publish sequence. The maxRate limit is checked at the end of each burst.
consumer-zmq-* zmqOptions string Additional ZMQ options, as a comma-separated list of key=value pairs. Possible keys: ZMQ_CONFLATE, ZMQ_IO_THREADS, ZMQ_LINGER, ZMQ_SNDBUF, ZMQ_SNDHWM, ZMQ_SNDTIMEO.
equipment-* autoTimeframeId int 0 When set, timeframe IDs are generated incrementally instead of being computed from trigger orbit counters. Useful to replay files with unordered / gap between TF. BC still used to detect boundaries between TFs.
equipment-* blockAlign bytes 2M Alignment of the beginning of the big memory block from which the pool is created. Pool will start at a multiple of this value. Each page will then begin at a multiple of memoryPoolPageSize from the beginning of big block.
equipment-* consoleStatsUpdateTime double 0 If set, number of seconds between printing statistics on console.
equipment-* ctpMode int 0 If set, the detector field (CTP run mask) is checked. Incoming data is discarded until a new bit is set, and discarded again after this bit is unset. Automatically implies rdhCheckDetectorField=1 and rdhCheckDetectorField=1.
equipment-* dataPagesLogPath string Path where to save a summary of each data pages generated by equipment.
equipment-* debugFirstPages int 0 If set, print debug information for first (given number of) data pages readout.
equipment-* disableOutput int 0 If non-zero, data generated by this equipment is discarded immediately and is not pushed to output fifo of readout thread. Used for testing.
equipment-* dropPagesWithError int 0 If set, the pages with RDH errors are discarded (requires rdhCheckEnabled or rdhUseFirstInPage).
equipment-* enabled int 1 Enable (value=1) or disable (value=0) the equipment.
equipment-* equipmentType string The type of equipment to be instanciated. One of: dummy, rorc, cruEmulator
equipment-* firstPageOffset bytes Offset of the first page, in bytes from the beginning of the memory pool. If not set (recommended), will start at memoryPoolPageSize (one free page is kept before the first usable page for readout internal use).
equipment-* id int Optional. Number used to identify equipment (used e.g. in file recording). Range 1-65535.
equipment-* idleSleepTime int 200 Thread idle sleep time, in microseconds.
equipment-* memoryBankName string Name of bank to be used. By default, it uses the first available bank declared.
equipment-* memoryPoolNumberOfPages int Number of pages to be created for this equipment, taken from the chosen memory bank. The bank should have enough free space to accomodate (memoryPoolNumberOfPages + 1) * memoryPoolPageSize bytes.
equipment-* memoryPoolPageSize bytes Size of each memory page to be created. Some space might be kept in each page for internal readout usage.
equipment-* name string Name used to identify this equipment (in logs). By default, it takes the name of the configuration section, equipment-xxx
equipment-* numaNode string auto If set, memory / thread will try to use given NUMA node. If "auto", will try to guess it for given equipment (eg ROC).
equipment-* outputFifoSize int -1 Size of output fifo (number of pages). If -1, set to the same value as memoryPoolNumberOfPages (this ensures that nothing can block the equipment while there are free pages).
equipment-* rdhCheckDetectorField int 0 If set, the detector field is checked and changes reported.
equipment-* rdhCheckEnabled int 0 If set, data pages are parsed and RDH headers checked. Errors are reported in logs.
equipment-* rdhCheckFirstOrbit int 1 If set, it is checked that the first orbit of all equipments and links is the same. If not, run is stopped.
equipment-* rdhCheckTrigger int 0 If set, the RDH trigger counters are checked for consistency.
equipment-* rdhDumpEnabled int 0 If set, data pages are parsed and RDH headers summary printed on console. Setting a negative number will print only the first N pages.
equipment-* rdhDumpErrorEnabled int 1 If set, a log message is printed for each RDH header error found.
equipment-* rdhDumpFirstInPageEnabled int 0 If set, the first RDH in each data page is logged. Setting a negative number will printit only for the first N pages.
equipment-* rdhDumpWarningEnabled int 1 If set, a log message is printed for each RDH header warning found.
equipment-* rdhUseFirstInPageEnabled int 0 or 1 If set, the first RDH in each data page is used to populate readout headers (e.g. linkId). Default is 1 for equipments generating data with RDH, 0 otherwsise.
equipment-* saveErrorPagesMax int 0 If set, pages found with data error are saved to disk up to given maximum.
equipment-* saveErrorPagesPath string Path where to save data pages with errors (when feature enabled).
equipment-* stopOnError int 0 If 1, readout will stop automatically on equipment error.
equipment-* TFperiod int 128 Duration of a timeframe, in number of LHC orbits.
equipment-* verbose int 0 If set, extra debug messages may be logged.
equipment-cruemulator-* cruBlockSize int 8192 Size of a RDH block.
equipment-cruemulator-* cruId int 0 CRU Id, used for CRU Id field in RDH.
equipment-cruemulator-* dpwId int 0 CRU end-point Id (data path wrapper id), used for DPW Id field in RDH.
equipment-cruemulator-* EmptyHbRatio double 0 Fraction of empty HBframes, to simulate triggered detectors.
equipment-cruemulator-* feeId int 0 Front-End Electronics Id, used for FEE Id field in RDH.
equipment-cruemulator-* HBperiod int 1 Interval between 2 HeartBeat triggers, in number of LHC orbits.
equipment-cruemulator-* linkId int 0 Id of first link. If numberOfLinks>1, ids will range from linkId to linkId+numberOfLinks-1.
equipment-cruemulator-* linkThroughput double 3.2 The data throughput of each link, in Gbps.
equipment-cruemulator-* maxBlocksPerPage int 0 [obsolete- not used]. Maximum number of blocks per page.
equipment-cruemulator-* numberOfLinks int 1 Number of GBT links simulated by equipment.
equipment-cruemulator-* PayloadSize int 64k Maximum payload size for each trigger. Actual size is randomized, and then split in a number of (cruBlockSize) packets.
equipment-cruemulator-* PayloadSizeStdev double 0.0 Standard deviation of randomized PayloadSize (no unit, as a fraction of PayloadSize).
equipment-cruemulator-* systemId int 19 System Id, used for System Id field in RDH. By default, using the TEST code.
equipment-cruemulator-* triggerRate double 0 If set, the HB frame rate is limited to given value in Hz (1 HBF per data page).
equipment-dummy-* eventMaxSize bytes 128k Maximum size of randomly generated event.
equipment-dummy-* eventMinSize bytes 128k Minimum size of randomly generated event.
equipment-dummy-* fillData int 0 Pattern used to fill data page: (0) no pattern used, data page is left untouched, with whatever values were in memory (1) incremental byte pattern (2) incremental word pattern, with one random word out of 5.
equipment-player-* autoChunk int 0 When set, the file is replayed once, and cut automatically in data pages compatible with memory bank settings and RDH information. In this mode the preLoad and fillPage options have no effect.
equipment-player-* autoChunkLoop int 0 When set, the file is replayed in loops. If value is negative, only that number of loop is executed (-5 -> 5x replay).
equipment-player-* filePath string Path of file containing data to be injected in readout.
equipment-player-* fillPage int 1 If 1, content of data file is copied multiple time in each data page until page is full (or almost full: on the last iteration, there is no partial copy if remaining space is smaller than full file size). If 0, data file is copied exactly once in each data page.
equipment-player-* preLoad int 1 If 1, data pages preloaded with file content on startup. If 0, data is copied at runtime.
equipment-player-* updateOrbits int 1 When set, trigger orbit counters in all RDH are modified for iterations after the first one (in file loop replay mode), so that they keep increasing.
equipment-rorc-* cardId string ID of the board to be used. Typically, a PCI bus device id. c.f. AliceO2::roc::Parameters.
equipment-rorc-* channelNumber int 0 Channel number of the board to be used. Typically 0 for CRU, or 0-5 for CRORC. c.f. AliceO2::roc::Parameters.
equipment-rorc-* cleanPageBeforeUse int 0 If set, data pages are filled with zero before being given for writing by device. Slow, but usefull to readout incomplete pages (driver currently does not return correctly number of bytes written in page.
equipment-rorc-* dataSource string Internal This parameter selects the data source used by ReadoutCard, c.f. AliceO2::roc::Parameters. It can be for CRU one of Fee, Ddg, Internal and for CRORC one of Fee, SIU, DIU, Internal.
equipment-rorc-* debugStatsEnabled int 0 If set, enable extra statistics about internal buffers status. (printed to stdout when stopping)
equipment-rorc-* firmwareCheckEnabled int 1 If set, RORC driver checks compatibility with detected firmware. Use 0 to bypass this check (eg new fw version not yet recognized by ReadoutCard version).
equipment-rorc-* firmwareVersionsAllowed string Comma-separated list of ROC firmware versions allowed (6-digit hash). If empty, all are allowed.
equipment-rorc-* firmwareVersionsDenied string e4a5a46e Comma-separated list of ROC firmware versions denied (6-digit hash), i.e. which would cause configuration to abort.
equipment-zmq-* address string Address of remote server to connect, eg tcp://remoteHost:12345.
equipment-zmq-* mode string stream Possible values: stream (1 input ZMQ message = 1 output data page), snapshot (last ZMQ message = one output data page per TF).
equipment-zmq-* timeframeClientUrl string The address to be used to retrieve current timeframe. When set, data is published only once for each TF id published by remote server.
equipment-zmq-* type string SUB Type of ZMQ socket to use to get data (PULL, SUB).
readout aggregatorSliceTimeout double 0 When set, slices (groups) of pages are flushed if not updated after given timeout (otherwise closed only on beginning of next TF, or on stop).
readout aggregatorStfTimeout double 0 When set, subtimeframes are buffered until timeout (otherwise, sent immediately and independently for each data source).
readout customCommands string List of key=value pairs defining some custom shell commands to be executed at before/after state change commands.
readout defaults string If set, the corresponding configuration URI is loaded and merged with current readout configuration. Existing parameters in current config are NOT overwritten.
readout disableAggregatorSlicing int 0 When set, the aggregator slicing is disabled, data pages are passed through without grouping/slicing.
readout disableTimeframes int 0 When set, all timeframe related features are disabled (this may supersede other config parameters).
readout exitTimeout double -1 Time in seconds after which the program exits automatically. -1 for unlimited.
readout fairmqConsoleSeverity int -1 Select amount of FMQ messages with fair::Logger::SetConsoleSeverity(). Value as defined in Severity enum defined from FairLogger/Logger.h. Use -1 to leave current setting.
readout flushConsumerTimeout double 1 Time in seconds to wait before stopping the consumers (ie wait allocated pages released). 0 means stop immediately.
readout flushEquipmentTimeout double 1 Time in seconds to wait for data once the equipments are stopped. 0 means stop immediately.
readout logbookEnabled int 0 When set, the logbook is enabled and populated with readout stats at runtime.
readout logbookUpdateInterval int 30 Amount of time (in seconds) between logbook publish updates.
readout logbookUrl string The address to be used for the logbook API.
readout maxMsgError int 0 If non-zero, maximum number of error messages allowed while running. Readout stops when threshold is reached.
readout maxMsgWarning int 0 If non-zero, maximum number of error messages allowed while running. Readout stops when threshold is reached.
readout memoryPoolStatsEnabled int 0 Global debugging flag to enable statistics on memory pool usage (printed to stdout when pool released).
readout numberOfRuns int 1 In standalone mode, number of runs to execute (ie START/STOP cycles).
readout rate double -1 Data rate limit, per equipment, in Hertz. -1 for unlimited.
readout tfRateLimit double 0 When set, the output is limited to a given timeframe rate.
readout tfRateLimitMode int 0 Defines the source for TF rate limit: 0 = use TF id, 1 = use number of TF.
readout timeframeServerUrl string The address to be used to publish current timeframe, e.g. to be used as reference clock for other readout instances.
readout timeStart string In standalone mode, time at which to execute start. If not set, immediately.
readout timeStop string In standalone mode, time at which to execute stop. If not set, on int/term/quit signal.
readout-monitor broadcastHost string used by readout-status to connect to readout-monitor broadcast channel.
readout-monitor broadcastPort int 0 when set, the process will create a listening TCP port and broadcast statistics to connected clients.
readout-monitor logFile string when set, the process will log received metrics to a file.
readout-monitor logFileHistory int 1 defines the maximum number of previous log files to keep, when a maximum size is set.
readout-monitor logFileMaxSize int 128 defines the maximum size of log file (in MB). When reaching this threshold, the log file is rotated.
readout-monitor monitorAddress string tcp://127.0.0.1:6008 Address of the receiving ZeroMQ channel to receive readout statistics.
readout-monitor outputFormat int 0 0: default, human readable. 1: raw bytes.
receiverFMQ channelAddress string ipc:///tmp/pipe-readout c.f. parameter with same name in consumer-FairMQchannel-*
receiverFMQ channelName string readout c.f. parameter with same name in consumer-FairMQchannel-*
receiverFMQ channelType string pair c.f. parameter with same name in consumer-FairMQchannel-*
receiverFMQ decodingMode string none Decoding mode of the readout FMQ output stream. Possible values: none (no decoding), stfHbf, stfSuperpage
receiverFMQ dumpRDH int 0 When set, the RDH of data received are printed (needs decodingMode=readout).
receiverFMQ dumpSTF int 0 When set, the STF header of data received are printed (needs decodingMode=stfHbf).
receiverFMQ dumpTF int 0 When set, a message is printed when a new timeframe is received. If the value is bigger than one, this specifies a periodic interval between TF print after the first one. (e.g. 100 would print TF 1, 100, 200, etc).
receiverFMQ releaseDelay double 0 When set, the messages received are not immediately released, but kept for specified time (s).
receiverFMQ transportType string shmem c.f. parameter with same name in consumer-FairMQchannel-*